Pro tip: the oiler at the yard asked why I bump the load test weight twice, and his reason stuck with me
Last week I was doing my annual load test on the 60-ton in Fresno and an old oiler named Ray stopped to watch me set the weights. He asked why I always bump the block a second time before I trust the reading, and when I said it was just habit, he told me a story about a rig in 1998 that passed the first lift but settled a half inch on the second. He said the steel doesn't lie, but it takes a second set to show you its real shape. I've been running tests for 14 years and never thought about it that way. Now I do the double bump on purpose and write down both readings. Does anyone else log two readings on a load test, or is one pass enough for you?